This pump conforms to Directive 94/9/EC relating to equipment intended for use in potentially explosive atmospheres and is ATEX (ATmosphere EXplosible) certified. |
 |
 |
Marshalsea Hydraulics has been assessed by SGS Société Générale de Surveillance SA and certified as meeting the requirements of ISO 9001:2000 for the design, development, manufacture and servicing of hydraulic pumps, relief valves and intensifiers. |

 |
Pressure and flow combinations

Pump No. |
No. of pistons and size (ins) |
Theoretical flow (cc/rev) |
Max pres. (bar) |
Water cooled |
|
11470 51CC |
3 x 0.375 x 1/3 |
1.17 |
1,000 |
|
|
11470 52CC |
3 x 0.437 x 1/3 |
1.59 |
0,850 |
|
|
11470 53CC |
3 x 0.500 x 1/3 |
2.08 |
0,690 |
|
|
11470 61CC |
3 x 0.375 x 2/3 |
2.30 |
1,000 |
|
|
11470 62CC |
3 x 0.437 x 2/3 |
3.20 |
0,850 |
|
|
11470 63CC |
3 x 0.500 x 2/3 |
4.16 |
0,690 |
|
|
11470 51CC |
3 x 0.375 x 1/3 |
1.17 |
1,000 |
 |
|
11470 52CC |
3 x 0.437 x 1/3 |
1.59 |
0,850 |
 |
|
11470 53CC |
3 x 0.500 x 1/3 |
2.08 |
0,690 |
 |
|
11470 61CC |
3 x 0.375 x 2/3 |
2.30 |
1,000 |
 |
|
11470 62CC |
3 x 0.437 x 2/3 |
3.20 |
0,850 |
 |
|
11470 63CC |
3 x 0.500 x 2/3 |
4.16 |
0,690 |
 |
|
11480 51CC |
6 x 0.375 x 1/3 |
2.34 |
0,690 |
|
|
11480 52CC |
6 x 0.437 x 1/3 |
3.18 |
0,690 |
|
|
11480 53CC |
6 x 0.500 x 1/3 |
4.16 |
0,690 |
|
|
11480 61CC |
6 x 0.375 x 2/3 |
4.60 |
0,690 |
|
|
11480 62CC |
6 x 0.437 x 2/3 |
6.40 |
0,690 |
|
|
11480 63CC |
6 x 0.500 x 2/3 |
8.32 |
0,690 |
|
|
11480 51CC |
6 x 0.375 x 1/3 |
2.34 |
0,690 |
 |
|
11480 52CC |
6 x 0.437 x 1/3 |
3.18 |
0,690 |
 |
|
11480 53CC |
6 x 0.500 x 1/3 |
4.16 |
0,690 |
 |
|
11480 61CC |
6 x 0.375 x 2/3 |
4.60 |
0,690 |
 |
|
11480 62CC |
6 x 0.437 x 2/3 |
6.40 |
0,690 |
 |
|
11480 63CC |
6 x 0.500 x 2/3 |
8.32 |
0,690 |
 |
|

|

Installation

Rotation is bi-directional and the pump may be mounted horizontally or vertically. If vertical mounting is selected, our Technical Department should be consulted.

A suction filter of at least 55 microns should be used, and care should be taken to ensure that the filter is of adequate size and does not cause more than 300 mm Hg depression.
Pipes should be of sufficient size to give not more than 3.70 m/sec velocity in the delivery line and 1.20 m/sec in the suction line.

The suction line should be kept under positive pressure when the pump is stationary to allow priming.

We recommend that the fluid reservoir should be between 50 mm and 3 m above the suction port.

Material

316 stainless steel wetted parts; ceramic pistons; cast iron casing. Weight 47 Kg.
|
|
 |