Type XWH water glycol pump/motor pump unit



HOME


PUMPS, MOTOR PUMP UNITS

Water/Glycol pumps

Water pumps

Oil pumps


PRESSURE INTENSIFIERS

Topside use

Subsea applications


DOWN HOLE POWER PACK


VALVES

Relief valves

Thermal relief

Directional valves

Slide valves

Shutdown, lockout relay,

excess flow, flowline pilot


GENERAL

About us

Quality

Contact




WATER GLYCOL PUMPS

Type XW

XW installation and start up

Type XWH

Comparison of pump types

Testimonials

Ultra compact for given pressure and flow rates
Flow/pressure combinations within 50 Kw range
– up to 187 l/m or up to 636 bar
All external components 316 stainless steel
Competitively priced
No external lubrication or cooling systems
Direct drive – no external pulleys

The high pressure 50Kw (200 Kg) Type XWH hydraulic pump is specifically designed for water-based fluids. Separation of the lubricating oil and the pumped fluid is achieved by the installation of a cavity between the cylinder block and the case. Bypass from the pistons is collected in this cavity and returned to the inlet side of the pump. The XWH pump incorporates six axial pistons actuated by a single rotating swash plate.

The pump can be supplied with duplex deliveries which may be used for simultaneous high and low pressure applications when used in conjunction with an automatic unloading valve.



SimplexDuplex


Various combinations of flows and pressures are possible within the 40 kw range up to a maximum of 636 bar at 46 litres/min or up to 187 litres/min at 155 bar – see table on the right.

Applications

This high powered pump is highly suitable for Blow Out Preventer (BOP) applications, hydraulic power units (HPUs) and flushing skids.

Material

All external components manufactured from 316 stainless steel – pump shaft is medium carbon steel EN9 or EN8M.

Weight

200 Kg

 

Pump characteristics options

  Piston Theoretical flow Max pressure
Pump No. size (ins) cc/rev l/m USg/m bar psi
21400–01 6 x 0.625   26   46 12.0 636 9,225
21400–02 6 x 0.688   32   56 14.8 517 7,499
21400–03 6 x 0.750   38   67 17.6 435 6,309
21400–04 6 x 0.813   45   79 20.8 368 5,337
21400–05 6 x 0.875   52   91 24.0 318 4,612
21400–06 6 x 0.938   60 105 27.7 275 3,989
21400–07 6 x 1.000   68 119 31.4 243 3,524
21400–08 6 x 1.063   77 135 35.6 215 3,118
21400–09 6 x 1.125   86 151 39.8 192 2,785
21400–10 6 x 1.188   96 168 44.4 172 2,495
21400–11 6 x 1.250 107 187 49.5 155 2,248
Pressure and flow combinations are at 1,750rpm.

Installation

Rotation is bi-directional and the pump may be mounted horizontally or vertically.

A suction filter of at least 60 microns should be used, and care should be taken to ensure that the filter is of adequate size and does not cause more than 300 mm Hg depression.

Pipes should be of sufficient size to give not more than 3.7m/sec velocity in the delivery line and 1.2m/sec in the suction line. The suction line should be kept under positive pressure when the pump is stationary to allow priming.


Drawing



© Marshalsea Hydraulics Limited – a member of the Bifold Fluidpower group of companies.

Website by Big Bird Design