This pump conforms to Directive 94/9/EC relating to equipment intended for use in potentially explosive atmospheres and is ATEX (ATmosphere EXplosible) certified. |
 |
 |
Marshalsea Hydraulics has been assessed by SGS Société Générale de Surveillance SA and certified as meeting the requirements of ISO 9001:2000 for the design, development, manufacture and servicing of hydraulic pumps, relief valves and intensifiers. |

 |
Pressure and flow combinations

| Pump No. |
Piston size |
Stroke length |
Theoretical flow (cc/rev) |
Max pres. (bar) |
| Three piston versions |
|
07400 – 41 |
3 x 0.375 |
full |
03.52 |
690 |
|
07400 – 42 |
3 x 0.437 |
full |
04.80 |
690 |
|
07400 – 43 |
3 x 0.500 |
full |
06.25 |
663 |
|
07400 – 44 |
3 x 0.562 |
full |
07.90 |
524 |
|
07400 – 45 |
3 x 0.625 |
full |
09.79 |
423 |
|
07400 – 46 |
3 x 0.687 |
full |
11.79 |
351 |
|
07400 – 51 |
3 x 0.375 |
1/3 |
01.17 |
690 |
|
07400 – 52 |
3 x 0.437 |
1/3 |
01.59 |
690 |
|
07400 – 53 |
3 x 0.500 |
1/3 |
02.08 |
663 |
|
07400 – 54 |
3 x 0.562 |
1/3 |
02.63 |
524 |
|
07400 – 55 |
3 x 0.625 |
1/3 |
03.20 |
423 |
|
07400 – 56 |
3 x 0.687 |
1/3 |
03.93 |
351 |
|
07400 – 61 |
3 x 0.375 |
2/3 |
02.34 |
690 |
|
07400 – 62 |
3 x 0.437 |
2/3 |
03.20 |
690 |
|
07400 – 63 |
3 x 0.500 |
2/3 |
04.16 |
663 |
|
07400 – 64 |
3 x 0.562 |
2/3 |
05.26 |
524 |
|
07400 – 65 |
3 x 0.625 |
2/3 |
06.53 |
423 |
|
07400 – 66 |
3 x 0.687 |
2/3 |
07.86 |
351 |
|
07400 – 71 |
3 x 0.375 |
1/3 |
01.17 |
950 |
|
07400 – 72 |
3 x 0.437 |
1/3 |
01.59 |
950 |
|
07400 – 81 |
3 x 0.375 |
2/3 |
02.34 |
950 |
|
07400 – 82 |
3 x 0.437 |
2/3 |
03.20 |
950 |
| Six piston versions |
|
07410 – 41 |
6 x 0.375 |
full |
07.17 |
577 |
|
07410 – 42 |
6 x 0.437 |
full |
09.58 |
430 |
|
07410 – 43 |
6 x 0.500 |
full |
12.50 |
331 |
|
07410 – 44 |
6 x 0.562 |
full |
15.80 |
262 |
|
07410 – 45 |
6 x 0.625 |
full |
19.58 |
211 |
|
07410 – 46 |
6 x 0.687 |
full |
23.58 |
175 |
| Pump output is proportional to drive speed to a maximum of 1,800 rpm. Short stroke versions of this pump are also available for low flow applications. |
|

|

Material

Cast iron casing. Mild steel cylinder block/shaft. (Other materials available for special purposes).

Fluids

A mineral-based oil is recommended with additives to resist corrosion, oxidisation and foaming.

System temperature

Minimum 10°C; maximum + 70°C.

Drive speed

Maximum 1800 rpm.

Weight

35 Kg. |

Installation

Rotation is bi-directional and the pump may be mounted horizontally or vertically using a three piece flexible drive coupling between the pump and prime mover. If vertical mounting is selected, our Technical Department should be consulted.

A suction filter of at least 125 microns should be used, and care should be taken to ensure that the filter is of adequate size and does not cause more than 300 mm Hg depression at the pump suction port when operating at full flow.

A return line filter of 10 microns rating should be fitted.
|

|

Pipes should be of sufficient size to give not more than 3.70 m/sec (12 ft/sec) fluid velocity in the delivery line and not more than 1.20 m/sec (4 ft/sec) in the suction line.

We recommend that the fluid reservoir should be between 50 mm (2 in) and 3 m (10ft) above the suction port.

A safety relief valve set at the maximum pump rating should be fitted immediately downstream of the pump delivery port.

Maintenance instructions and a spares list are provided with each pump.
|
|
 |